Type some words to find content.
eg: fuse, arrestor, 00110115 technical, MCCB...
Recent searches
Tehnical support
This email address is being protected from spambots. You need JavaScript enabled to view it.
Filter type
Clear all
Expand all
Open all
86
Rated AC voltage (V)
18
18
18
17
15
Rated current (A)
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
4
4
3
Size
18
18
18
17
15
86

VVA (without striker pin)

Items: 0
004221102
VVA3 7,2kV/1A
Class name:
Fuse link
Cold resistance (mΩ):
1170
Rated minimum breaking current (A):
12
Rated current (A):
1
Type:
NEW VVA without striker
004221103
VVA3 7,2kV/2A
Class name:
Fuse link
Cold resistance (mΩ):
580
Rated minimum breaking current (A):
12
Rated current (A):
2
Type:
NEW VVA without striker
004221104
VVA3 7,2kV/4A
Class name:
Fuse link
Cold resistance (mΩ):
370
Rated minimum breaking current (A):
20
Rated current (A):
4
Type:
NEW VVA without striker
004221105
VVA3 7,2kV/6A
Class name:
Fuse link
Cold resistance (mΩ):
260
Rated minimum breaking current (A):
25
Rated current (A):
6
Type:
NEW VVA without striker
004221106
VVA3 7,2kV/6,3A
Class name:
Fuse link
Cold resistance (mΩ):
260
Rated minimum breaking current (A):
25
Rated current (A):
6.3
Type:
NEW VVA without striker
004221107
VVA3 7,2kV/10A
Class name:
Fuse link
Cold resistance (mΩ):
75
Rated minimum breaking current (A):
43
Rated current (A):
10
Type:
NEW VVA without striker
004221108
VVA3 7,2kV/16A
Class name:
Fuse link
Cold resistance (mΩ):
44
Rated minimum breaking current (A):
56
Rated current (A):
16
Type:
NEW VVA without striker
004221109
VVA3 7,2kV/20A
Class name:
Fuse link
Cold resistance (mΩ):
27
Rated minimum breaking current (A):
70
Rated current (A):
20
Type:
NEW VVA without striker
004221110
VVA3 7,2kV/25A
Class name:
Fuse link
Cold resistance (mΩ):
21
Rated minimum breaking current (A):
87
Rated current (A):
25
Type:
NEW VVA without striker
004221111
VVA3 7,2kV/31,5A
Class name:
Fuse link
Cold resistance (mΩ):
18
Rated minimum breaking current (A):
110
Rated current (A):
31.5
Type:
NEW VVA without striker
004221112
VVA3 7,2kV/32A
Class name:
Fuse link
Cold resistance (mΩ):
18
Rated minimum breaking current (A):
110
Rated current (A):
32
Type:
NEW VVA without striker
004221113
VVA3 7,2kV/40A
Class name:
Fuse link
Cold resistance (mΩ):
13
Rated minimum breaking current (A):
140
Rated current (A):
40
Type:
NEW VVA without striker
004221114
VVA3 7,2kV/50A
Class name:
Fuse link
Cold resistance (mΩ):
10.5
Rated minimum breaking current (A):
175
Rated current (A):
50
Type:
NEW VVA without striker
004221115
VVA3 7,2kV/63A
Class name:
Fuse link
Cold resistance (mΩ):
7.5
Rated minimum breaking current (A):
220
Rated current (A):
63
Type:
NEW VVA without striker
004221116
VVA3 7,2kV/80A
Class name:
Fuse link
Cold resistance (mΩ):
5.9
Rated minimum breaking current (A):
280
Rated current (A):
80
Type:
NEW VVA without striker
004221117
VVA3 7,2kV/100A
Class name:
Fuse link
Cold resistance (mΩ):
4.8
Rated minimum breaking current (A):
360
Rated current (A):
100
Type:
NEW VVA without striker
004221118
VVA3 7,2kV/125A
Class name:
Fuse link
Cold resistance (mΩ):
3.9
Rated minimum breaking current (A):
450
Rated current (A):
125
Type:
NEW VVA without striker
004221119
VVA3 7,2kV/160A
Class name:
Fuse link
Cold resistance (mΩ):
3
Rated minimum breaking current (A):
600
Rated current (A):
160
Type:
NEW VVA without striker
004231102
VVA3 12kV/1A
Class name:
Fuse link
Cold resistance (mΩ):
1970
Rated minimum breaking current (A):
12
Rated current (A):
1
Type:
NEW VVA without striker
004231103
VVA3 12kV/2A
Class name:
Fuse link
Cold resistance (mΩ):
980
Rated minimum breaking current (A):
12
Rated current (A):
2
Type:
NEW VVA without striker
004231104
VVA3 12kV/4A
Class name:
Fuse link
Cold resistance (mΩ):
650
Rated minimum breaking current (A):
20
Rated current (A):
4
Type:
NEW VVA without striker
004231105
VVA3 12kV/6A
Class name:
Fuse link
Cold resistance (mΩ):
435
Rated minimum breaking current (A):
25
Rated current (A):
6
Type:
NEW VVA without striker
004231106
VVA3 12kV/6,3A
Class name:
Fuse link
Cold resistance (mΩ):
435
Rated minimum breaking current (A):
25
Rated current (A):
6.3
Type:
NEW VVA without striker
004231107
VVA3 12kV/10A
Class name:
Fuse link
Cold resistance (mΩ):
130
Rated minimum breaking current (A):
43
Rated current (A):
10
Type:
NEW VVA without striker
004231108
VVA3 12kV/16A
Class name:
Fuse link
Cold resistance (mΩ):
70
Rated minimum breaking current (A):
56
Rated current (A):
16
Type:
NEW VVA without striker
004231109
VVA3 12kV/20A
Class name:
Fuse link
Cold resistance (mΩ):
44
Rated minimum breaking current (A):
70
Rated current (A):
20
Type:
NEW VVA without striker
004231110
VVA3 12kV/25A
Class name:
Fuse link
Cold resistance (mΩ):
33
Rated minimum breaking current (A):
87
Rated current (A):
25
Type:
NEW VVA without striker
004231111
VVA3 12kV/31,5A
Class name:
Fuse link
Cold resistance (mΩ):
29
Rated minimum breaking current (A):
110
Rated current (A):
31.5
Type:
NEW VVA without striker
004231112
VVA3 12kV/32A
Class name:
Fuse link
Cold resistance (mΩ):
29
Rated minimum breaking current (A):
110
Rated current (A):
32
Type:
NEW VVA without striker
004231113
VVA3 12kV/40A
Class name:
Fuse link
Cold resistance (mΩ):
21.5
Rated minimum breaking current (A):
140
Rated current (A):
40
Type:
NEW VVA without striker
004231114
VVA3 12kV/50A
Class name:
Fuse link
Cold resistance (mΩ):
16.5
Rated minimum breaking current (A):
175
Rated current (A):
50
Type:
NEW VVA without striker
004231115
VVA3 12kV/63A
Class name:
Fuse link
Cold resistance (mΩ):
12
Rated minimum breaking current (A):
220
Rated current (A):
63
Type:
NEW VVA without striker
004231116
VVA3 12kV/80A
Class name:
Fuse link
Cold resistance (mΩ):
9
Rated minimum breaking current (A):
280
Rated current (A):
80
Type:
NEW VVA without striker
004231117
VVA3 12kV/100A
Class name:
Fuse link
Cold resistance (mΩ):
6.7
Rated minimum breaking current (A):
360
Rated current (A):
100
Type:
NEW VVA without striker
004231118
VVA3 12kV/125A
Class name:
Fuse link
Cold resistance (mΩ):
5.2
Rated minimum breaking current (A):
450
Rated current (A):
125
Type:
NEW VVA without striker
004231119
VVA3 12kV/160A
Class name:
Fuse link
Cold resistance (mΩ):
4.1
Rated minimum breaking current (A):
600
Rated current (A):
160
Type:
NEW VVA without striker
004241102
VVA3 17,5kV/1A
Class name:
Fuse link
Cold resistance (mΩ):
2800
Rated minimum breaking current (A):
12
Rated current (A):
1
Type:
NEW VVA without striker
004241103
VVA3 17,5kV/2A
Class name:
Fuse link
Cold resistance (mΩ):
1400
Rated minimum breaking current (A):
12
Rated current (A):
2
Type:
NEW VVA without striker
004241104
VVA3 17,5kV/4A
Class name:
Fuse link
Cold resistance (mΩ):
900
Rated minimum breaking current (A):
20
Rated current (A):
4
Type:
NEW VVA without striker
004241105
VVA3 17,5kV/6A
Class name:
Fuse link
Cold resistance (mΩ):
670
Rated minimum breaking current (A):
25
Rated current (A):
6
Type:
NEW VVA without striker
>
>
0