Type some words to find content eg:
fuse,arrestor,00110115 technical...
Recent searches
Tehnical support
This email address is being protected from spambots. You need JavaScript enabled to view it.
Filter type
Clear all
Expand all
Open all
86
Rated AC voltage (V)
18
18
18
17
15
Rated current (A)
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
4
4
3
Size
18
18
18
17
15
86

VVA

Items: 0 New items: 86
004221102
New
VVA3 7,2kV/1A
Class name:
Fuse link
Rated minimum breaking current (A):
12
Cold resistance (mΩ):
1170
Rated current (A):
1
Type:
NEW VVA without striker
004221103
New
VVA3 7,2kV/2A
Class name:
Fuse link
Rated minimum breaking current (A):
12
Cold resistance (mΩ):
580
Rated current (A):
2
Type:
NEW VVA without striker
004221104
New
VVA3 7,2kV/4A
Class name:
Fuse link
Rated minimum breaking current (A):
20
Cold resistance (mΩ):
370
Rated current (A):
4
Type:
NEW VVA without striker
004221105
New
VVA3 7,2kV/6A
Class name:
Fuse link
Rated minimum breaking current (A):
25
Cold resistance (mΩ):
260
Rated current (A):
6
Type:
NEW VVA without striker
004221106
New
VVA3 7,2kV/6,3A
Class name:
Fuse link
Rated minimum breaking current (A):
25
Cold resistance (mΩ):
260
Rated current (A):
6.3
Type:
NEW VVA without striker
004221107
New
VVA3 7,2kV/10A
Class name:
Fuse link
Rated minimum breaking current (A):
43
Cold resistance (mΩ):
75
Rated current (A):
10
Type:
NEW VVA without striker
004221108
New
VVA3 7,2kV/16A
Class name:
Fuse link
Rated minimum breaking current (A):
56
Cold resistance (mΩ):
44
Rated current (A):
16
Type:
NEW VVA without striker
004221109
New
VVA3 7,2kV/20A
Class name:
Fuse link
Rated minimum breaking current (A):
70
Cold resistance (mΩ):
27
Rated current (A):
20
Type:
NEW VVA without striker
004221110
New
VVA3 7,2kV/25A
Class name:
Fuse link
Rated minimum breaking current (A):
87
Cold resistance (mΩ):
21
Rated current (A):
25
Type:
NEW VVA without striker
004221111
New
VVA3 7,2kV/31,5A
Class name:
Fuse link
Rated minimum breaking current (A):
110
Cold resistance (mΩ):
18
Rated current (A):
31.5
Type:
NEW VVA without striker
004221112
New
VVA3 7,2kV/32A
Class name:
Fuse link
Rated minimum breaking current (A):
110
Cold resistance (mΩ):
18
Rated current (A):
32
Type:
NEW VVA without striker
004221113
New
VVA3 7,2kV/40A
Class name:
Fuse link
Rated minimum breaking current (A):
140
Cold resistance (mΩ):
13
Rated current (A):
40
Type:
NEW VVA without striker
004221114
New
VVA3 7,2kV/50A
Class name:
Fuse link
Rated minimum breaking current (A):
175
Cold resistance (mΩ):
10.5
Rated current (A):
50
Type:
NEW VVA without striker
004221115
New
VVA3 7,2kV/63A
Class name:
Fuse link
Rated minimum breaking current (A):
220
Cold resistance (mΩ):
7.5
Rated current (A):
63
Type:
NEW VVA without striker
004221116
New
VVA3 7,2kV/80A
Class name:
Fuse link
Rated minimum breaking current (A):
280
Cold resistance (mΩ):
5.9
Rated current (A):
80
Type:
NEW VVA without striker
004221117
New
VVA3 7,2kV/100A
Class name:
Fuse link
Rated minimum breaking current (A):
360
Cold resistance (mΩ):
4.8
Rated current (A):
100
Type:
NEW VVA without striker
004221118
New
VVA3 7,2kV/125A
Class name:
Fuse link
Rated minimum breaking current (A):
450
Cold resistance (mΩ):
3.9
Rated current (A):
125
Type:
NEW VVA without striker
004221119
New
VVA3 7,2kV/160A
Class name:
Fuse link
Rated minimum breaking current (A):
600
Cold resistance (mΩ):
3
Rated current (A):
160
Type:
NEW VVA without striker
004231102
New
VVA3 12kV/1A
Class name:
Fuse link
Rated minimum breaking current (A):
12
Cold resistance (mΩ):
1970
Rated current (A):
1
Type:
NEW VVA without striker
004231103
New
VVA3 12kV/2A
Class name:
Fuse link
Rated minimum breaking current (A):
12
Cold resistance (mΩ):
980
Rated current (A):
2
Type:
NEW VVA without striker
004231104
New
VVA3 12kV/4A
Class name:
Fuse link
Rated minimum breaking current (A):
20
Cold resistance (mΩ):
650
Rated current (A):
4
Type:
NEW VVA without striker
004231105
New
VVA3 12kV/6A
Class name:
Fuse link
Rated minimum breaking current (A):
25
Cold resistance (mΩ):
435
Rated current (A):
6
Type:
NEW VVA without striker
004231106
New
VVA3 12kV/6,3A
Class name:
Fuse link
Rated minimum breaking current (A):
25
Cold resistance (mΩ):
435
Rated current (A):
6.3
Type:
NEW VVA without striker
004231107
New
VVA3 12kV/10A
Class name:
Fuse link
Rated minimum breaking current (A):
43
Cold resistance (mΩ):
130
Rated current (A):
10
Type:
NEW VVA without striker
004231108
New
VVA3 12kV/16A
Class name:
Fuse link
Rated minimum breaking current (A):
56
Cold resistance (mΩ):
70
Rated current (A):
16
Type:
NEW VVA without striker
004231109
New
VVA3 12kV/20A
Class name:
Fuse link
Rated minimum breaking current (A):
70
Cold resistance (mΩ):
44
Rated current (A):
20
Type:
NEW VVA without striker
004231110
New
VVA3 12kV/25A
Class name:
Fuse link
Rated minimum breaking current (A):
87
Cold resistance (mΩ):
33
Rated current (A):
25
Type:
NEW VVA without striker
004231111
New
VVA3 12kV/31,5A
Class name:
Fuse link
Rated minimum breaking current (A):
110
Cold resistance (mΩ):
29
Rated current (A):
31.5
Type:
NEW VVA without striker
004231112
New
VVA3 12kV/32A
Class name:
Fuse link
Rated minimum breaking current (A):
110
Cold resistance (mΩ):
29
Rated current (A):
32
Type:
NEW VVA without striker
004231113
New
VVA3 12kV/40A
Class name:
Fuse link
Rated minimum breaking current (A):
140
Cold resistance (mΩ):
21
Rated current (A):
40
Type:
NEW VVA without striker
004231114
New
VVA3 12kV/50A
Class name:
Fuse link
Rated minimum breaking current (A):
175
Cold resistance (mΩ):
16.5
Rated current (A):
50
Type:
NEW VVA without striker
004231115
New
VVA3 12kV/63A
Class name:
Fuse link
Rated minimum breaking current (A):
220
Cold resistance (mΩ):
12
Rated current (A):
63
Type:
NEW VVA without striker
004231116
New
VVA3 12kV/80A
Class name:
Fuse link
Rated minimum breaking current (A):
280
Cold resistance (mΩ):
9
Rated current (A):
80
Type:
NEW VVA without striker
004231117
New
VVA3 12kV/100A
Class name:
Fuse link
Rated minimum breaking current (A):
360
Cold resistance (mΩ):
6.7
Rated current (A):
100
Type:
NEW VVA without striker
004231118
New
VVA3 12kV/125A
Class name:
Fuse link
Rated minimum breaking current (A):
450
Cold resistance (mΩ):
5.2
Rated current (A):
125
Type:
NEW VVA without striker
004231119
New
VVA3 12kV/160A
Class name:
Fuse link
Rated minimum breaking current (A):
600
Cold resistance (mΩ):
4.1
Rated current (A):
160
Type:
NEW VVA without striker
004241102
New
VVA3 17,5kV/1A
Class name:
Fuse link
Rated minimum breaking current (A):
12
Cold resistance (mΩ):
2800
Rated current (A):
1
Type:
NEW VVA without striker
004241103
New
VVA3 17,5kV/2A
Class name:
Fuse link
Rated minimum breaking current (A):
12
Cold resistance (mΩ):
1400
Rated current (A):
2
Type:
NEW VVA without striker
004241104
New
VVA3 17,5kV/4A
Class name:
Fuse link
Rated minimum breaking current (A):
20
Cold resistance (mΩ):
900
Rated current (A):
4
Type:
NEW VVA without striker
004241105
New
VVA3 17,5kV/6A
Class name:
Fuse link
Rated minimum breaking current (A):
25
Cold resistance (mΩ):
670
Rated current (A):
6
Type:
NEW VVA without striker
>
>
0
Your basket is empty.