Fuses for TVSS products protection

Items: 0
002636004
10
CH14x51 SRF10 /600V
Class name: Fuse link
Type: CH
Size: CH14
Surge Rating for SRF Fuse: 10.000
Rated AC voltage (V): 600
002636005
10
CH14x51 SRF20 /600V
Class name: Fuse link
Type: CH
Size: CH14
Surge Rating for SRF Fuse: 20.000
Rated AC voltage (V): 600
002636006
10
CH14x51 SRF30 /600V
Class name: Fuse link
Type: CH
Size: CH14
Surge Rating for SRF Fuse: 30.000
Rated AC voltage (V): 600
002636007
10
CH14x51 SRF40 /600V
Class name: Fuse link
Type: CH
Size: CH14
Surge Rating for SRF Fuse: 40.000
Rated AC voltage (V): 600
002646006
10
Tal.vl.CH22x58 SRF60
Class name: Fuse link
Type: CH
Size: CH22
Surge Rating for SRF Fuse: 60.000
Rated AC voltage (V): 600
002646015
0
CH22x58 SRF3-II DC
Class name: Fuse link
Type: CH
Size: CH22
Surge Rating for SRF Fuse: 3.000
Rated AC voltage (V):
002646016
0
CH22x58 SRF8-II DC
Class name: Fuse link
Type: CH
Size: CH22
Surge Rating for SRF Fuse: 8.000
Rated AC voltage (V):
002646017
10
CH22x58 SRF12-II DC
Class name: Fuse link
Type: CH
Size: CH22
Surge Rating for SRF Fuse: 12.000
Rated AC voltage (V):
002646010
20
CH22x58 SRF25-I /400V
Class name: Fuse link
Type: CH
Size: CH22
Surge Rating for SRF Fuse: 25.000
Rated AC voltage (V): 400
{"records":[{"ID":"8160","eti_code":"002636004","descr":"CH14x51 SRF10 \/600V","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH14x51 CH CH14 II 10.000 600V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":"20","weight_em":"g","basic_packaging":"10","shipping_packaging":"200","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/2868_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002636004|Fuse link, CH14x51 SRF10 \/600V|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF class 2 - 8\/20\u03bcs|14x51|14x51|Special purpose fuses|Fuses for TVSS products protection|CH14X51 SRF10 \/6|Type CH|Size CH14|Product group Special purpose fuses|Product subgroup SRF|Rated AC voltage 600V|Dimensions 14x51|Breaking capacity AC 200kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 10.370A2s|Prearcing joule integral 2.360A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 10.000|Designed for 8 20 lighting surge pulses|Fuse link CH14x51 CH CH14 II 10.000 600V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH14","charact":"","rated_ac_voltage":"600","rated_dc_voltage":"","indicator":"","breaking_capacity_ac":"200","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"10.370","Prearcing_joule":"2.360","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"10.000","price":"7.5644","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"10","alias":"002636004-fuse-link-ch14x51-ch-ch14-ii-10-000-600v"},{"ID":"8158","eti_code":"002636005","descr":"CH14x51 SRF20 \/600V","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH14x51 CH CH14 II 20.000 600V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":".029","weight_em":"kg","basic_packaging":"10","shipping_packaging":"200","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/2868_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002636005|Fuse link, CH14x51 SRF20 \/600V|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF class 2 - 8\/20\u03bcs|14x51|14x51|Special purpose fuses|Fuses for TVSS products protection|CH14X51 SRF20 \/6|Type CH|Size CH14|Product group Special purpose fuses|Product subgroup SRF|Rated AC voltage 600V|Dimensions 14x51|Breaking capacity AC 200kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 17.700A2s|Prearcing joule integral 5.490A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 20.000|Designed for 8 20 lighting surge pulses|Fuse link CH14x51 CH CH14 II 20.000 600V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH14","charact":"","rated_ac_voltage":"600","rated_dc_voltage":"","indicator":"","breaking_capacity_ac":"200","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"17.700","Prearcing_joule":"5.490","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"20.000","price":"9.5645","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"-20.00","stock_status":"3","packaging_basic":"10","alias":"002636005-fuse-link-ch14x51-ch-ch14-ii-20-000-600v"},{"ID":"8159","eti_code":"002636006","descr":"CH14x51 SRF30 \/600V","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH14x51 CH CH14 II 30.000 600V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":"18.75","weight_em":"g","basic_packaging":"10","shipping_packaging":"200","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/2868_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002636006|Fuse link, CH14x51 SRF30 \/600V|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF class 2 - 8\/20\u03bcs|14x51|14x51|Special purpose fuses|Fuses for TVSS products protection|CH14X51 SRF30 \/|Type CH|Size CH14|Product group Special purpose fuses|Product subgroup SRF|Rated AC voltage 600V|Dimensions 14x51|Breaking capacity AC 200kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 39.880A2s|Prearcing joule integral 16.750A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 30.000|Designed for 8 20 lighting surge pulses|Fuse link CH14x51 CH CH14 II 30.000 600V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH14","charact":"","rated_ac_voltage":"600","rated_dc_voltage":"","indicator":"","breaking_capacity_ac":"200","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"39.880","Prearcing_joule":"16.750","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"30.000","price":"9.5645","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"170.00","stock_status":"1","packaging_basic":"10","alias":"002636006-fuse-link-ch14x51-ch-ch14-ii-30-000-600v"},{"ID":"8161","eti_code":"002636007","descr":"CH14x51 SRF40 \/600V","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH14x51 CH CH14 II 40.000 600V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":".02","weight_em":"kg","basic_packaging":"10","shipping_packaging":"200","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/2868_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002636007|Fuse link, CH14x51 SRF40 \/600V|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF class 2 - 8\/20\u03bcs|14x51|14x51|Special purpose fuses|Fuses for TVSS products protection|CH14X51 SRF40 \/6|Type CH|Size CH14|Product group Special purpose fuses|Product subgroup SRF|Rated AC voltage 600V|Dimensions 14x51|Breaking capacity AC 200kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 72.800A2s|Prearcing joule integral 33.680A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 40.000|Designed for 8 20 lighting surge pulses|Fuse link CH14x51 CH CH14 II 40.000 600V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH14","charact":"","rated_ac_voltage":"600","rated_dc_voltage":"","indicator":"","breaking_capacity_ac":"200","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"72.800","Prearcing_joule":"33.680","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"40.000","price":"10.7051","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"30.00","stock_status":"1","packaging_basic":"10","alias":"002636007-fuse-link-ch14x51-ch-ch14-ii-40-000-600v"},{"ID":"17656","eti_code":"002646006","descr":"Tal.vl.CH22x58 SRF60","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link Tal.vl.CH22x58 CH CH22 II 60.000 600V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":"52","weight_em":"g","basic_packaging":"10","shipping_packaging":"440","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/2868_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002646006|Fuse link, Tal.vl.CH22x58 SRF60|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF class 2 - 8\/20\u03bcs|22x58|22x58|Special purpose fuses|Fuses for TVSS products protection|TAL.VL.CH22X58 S|Type CH|Size CH22|Product group Special purpose fuses|Product subgroup SRF|Rated AC voltage 600V|Dimensions 22x58|Breaking capacity AC 200kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 247.180A2s|Prearcing joule integral 133.630A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 60.000|Designed for 8 20 lighting surge pulses|Fuse link Tal.vl.CH22x58 CH CH22 II 60.000 600V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH22","charact":"","rated_ac_voltage":"600","rated_dc_voltage":"","indicator":"","breaking_capacity_ac":"200","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"247.180","Prearcing_joule":"133.630","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"60.000","price":"10.7051","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"-200.00","stock_status":"3","packaging_basic":"10","alias":"002646006-fuse-link-tal-vl-ch22x58-ch-ch22-ii-60-000-600v"},{"ID":"45214","eti_code":"002646015","descr":"CH22x58 SRF3-II DC","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH22x58 CH CH22 II 3.000 1000V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":"53","weight_em":"g","basic_packaging":"10","shipping_packaging":"440","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4279_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002646015|Fuse link, CH22x58 SRF3-II DC|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF DC class 2 - 8\/20\u03bcs|22x58|22x58|Special purpose fuses|Fuses for TVSS products protection|CH22X58 SRF3-II|Type CH|Size CH22|Product group Special purpose fuses|Product subgroup SRF|Rated DC voltage 1000V|Dimensions 22x58|Breaking capacity DC 1kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 1.380A2s|Prearcing joule integral 660A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 3.000|Designed for 8 20?sec lighting surge pulses|Fuse link CH22x58 CH CH22 II 3.000 1000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH22","charact":"","rated_ac_voltage":"","rated_dc_voltage":"1000","indicator":"","breaking_capacity_ac":"","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"1.380","Prearcing_joule":"660","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"3.000","price":"15.0141","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"0","alias":"002646015-fuse-link-ch22x58-ch-ch22-ii-3-000-1000v"},{"ID":"45213","eti_code":"002646016","descr":"CH22x58 SRF8-II DC","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH22x58 CH CH22 II 8.000 1000V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":"53","weight_em":"g","basic_packaging":"10","shipping_packaging":"440","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4279_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002646016|Fuse link, CH22x58 SRF8-II DC|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF DC class 2 - 8\/20\u03bcs|22x58|22x58|Special purpose fuses|Fuses for TVSS products protection|CH22X58 SRF8-II|Type CH|Size CH22|Product group Special purpose fuses|Product subgroup SRF|Rated DC voltage 1000V|Dimensions 22x58|Breaking capacity DC 1kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 8.730A2s|Prearcing joule integral 6.930A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 8.000|Designed for 8 20?sec lighting surge pulses|Fuse link CH22x58 CH CH22 II 8.000 1000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH22","charact":"","rated_ac_voltage":"","rated_dc_voltage":"1000","indicator":"","breaking_capacity_ac":"","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"8.730","Prearcing_joule":"6.930","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"8.000","price":"15.0141","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"0","alias":"002646016-fuse-link-ch22x58-ch-ch22-ii-8-000-1000v"},{"ID":"45308","eti_code":"002646017","descr":"CH22x58 SRF12-II DC","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH22x58 CH CH22 II 12.000 1000V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":"53","weight_em":"g","basic_packaging":"10","shipping_packaging":"440","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4279_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002646017|Fuse link, CH22x58 SRF12-II DC|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF DC class 2 - 8\/20\u03bcs|22x58|22x58|Special purpose fuses|Fuses for TVSS products protection|CH22X58 SRF12-II|Type CH|Size CH22|Product group Special purpose fuses|Product subgroup SRF|Rated DC voltage 1000V|Dimensions 22x58|Breaking capacity DC 1kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category II|Standards Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.|Operating joule integral 86.500A2s|Prearcing joule integral 85.500A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 12.000|Designed for 8 20?sec lighting surge pulses|Fuse link CH22x58 CH CH22 II 12.000 1000V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH22","charact":"","rated_ac_voltage":"","rated_dc_voltage":"1000","indicator":"","breaking_capacity_ac":"","OvervoltageCategory":"II","Standards":"Comply with the applicable requirements in UL 248-1 Low Voltage Fuses- Part1, General Requirements.","Operating_joule":"86.500","Prearcing_joule":"85.500","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"12.000","price":"15.0141","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"10","alias":"002646017-fuse-link-ch22x58-ch-ch22-ii-12-000-1000v"},{"ID":"45215","eti_code":"002646010","descr":"CH22x58 SRF25-I \/400V","descr_uk_UA":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link CH22x58 CH CH22 I 25.000 400V","seo_alias":null,"class_name":"Fuse link","id_level":"467","weight":".055","weight_em":"kg","basic_packaging":"20","shipping_packaging":"240","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/4278_photo.jpg","tree_depth":"2","tree_title":"Fuses for TVSS products protection","program_type":"1","searchstring":"|002646010|Fuse link, CH22x58 SRF25-I \/400V|Special fuses|Fuses for TVSS products protection|SRF Series Surge Fuse|CH SRF 25kA class 1 - 10\/350\u03bcs|22x58|22x58|Special purpose fuses|Fuses for TVSS products protection|CH22X58 SRF25-I|Type CH|Size CH22|Product group Special purpose fuses|Product subgroup SRF|Rated AC voltage 400V|Dimensions 22x58|Breaking capacity AC 50kA|Catalogue Group Special purpose fuses|Catalogue subgroup TVSS Protection Fuse - SRF|Overvoltage Category I|Standards 61463-11|Operating joule integral 504.300A2s|Prearcing joule integral 322.700A2s|Application These fuses are intended for installation in series with TVSS devices|Surge Rating for SRF Fuse 25.000|Designed for 10 350 lighting surge pulses|Fuse link CH22x58 CH CH22 I 25.000 400V|","stockammount":"0","stockstatus":"0","preview_mode":"0","type":"CH","size":"CH22","charact":"","rated_ac_voltage":"400","rated_dc_voltage":"","indicator":"","breaking_capacity_ac":"50","OvervoltageCategory":"I","Standards":"61463-11","Operating_joule":"504.300","Prearcing_joule":"322.700","Application":"These fuses are intended for installation in series with TVSS devices","SRF_surge":"25.000","price":"15.6764","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"-20.00","stock_status":"3","packaging_basic":"20","alias":"002646010-fuse-link-ch22x58-ch-ch22-i-25-000-400v"}],"columns":[{"name":"eti_code","title":"ETI Code","primary":true},{"name":"descr","title":"Description","primary":false},{"name":"class_name","title":"Class name","primary":false},{"name":"type","title":"Type","primary":false},{"name":"Price","title":"COM_ETIB2B_ORDERS_TABLE_COLUMN_PRICE","cssClass":"price align-right","primary":false},{"name":"StockStatus","title":"COM_ETIB2B_ORDERS_TABLE_COLUMN_AVAILABILITY","primary":false},{"name":"Commands","title":"","primary":false}],"recordsCount":9,"recordsTotalCount":9,"params":{"filters":{"lang":"en-GB","levelId":467,"status":null,"search":null,"programType":0},"pageNumber":1,"pageSize":40,"pageMax":1,"dataEx":{"filterItems":{"type":{"field":"type","values":[{"count":"9","value":"CH"}],"trans":"Type"},"size":{"field":"size","values":[{"count":"4","value":"CH14"},{"count":"5","value":"CH22"}],"trans":"Size"},"SRF_surge":{"field":"SRF_surge","values":[{"count":"1","value":"3.000"},{"count":"1","value":"8.000"},{"count":"1","value":"10.000"},{"count":"1","value":"12.000"},{"count":"1","value":"20.000"},{"count":"1","value":"25.000"},{"count":"1","value":"30.000"},{"count":"1","value":"40.000"},{"count":"1","value":"60.000"}],"trans":"Surge Rating for SRF Fuse"},"rated_ac_voltage":{"field":"rated_ac_voltage","values":[{"count":"1","value":"400"},{"count":"5","value":"600"}],"trans":"Rated AC voltage (V)"},"rated_dc_voltage":{"field":"rated_dc_voltage","values":[{"count":"3","value":"1000"}],"trans":"Rated DC voltage (V)"},"charact":{"field":"charact","values":[],"trans":"Characteristics"},"OvervoltageCategory":{"field":"OvervoltageCategory","values":[{"count":"1","value":"I"},{"count":"8","value":"II"}],"trans":"Overvoltage Category"}},"columnsThumbs":[{"column":"class_name","title":"Class name"},{"column":"type","title":"Type"},{"column":"size","title":"Size"},{"column":"SRF_surge","title":"Surge Rating for SRF Fuse"},{"column":"rated_ac_voltage","title":"Rated AC voltage (V)"}],"columnsThumbsAll":[{"column":"class_name","title":"Class name"},{"column":"type","title":"Type"},{"column":"size","title":"Size"},{"column":"SRF_surge","title":"Surge Rating for SRF Fuse"},{"column":"rated_ac_voltage","title":"Rated AC voltage (V)"},{"column":"rated_dc_voltage","title":"Rated DC voltage (V)"},{"column":"charact","title":"Characteristics"},{"column":"breaking_capacity_ac","title":"Breaking capacity AC (kA)"},{"column":"OvervoltageCategory","title":"Overvoltage Category"},{"column":"Application","title":"Application"}],"programTypes":{"1":{"program_type":"1","Count":"9"}}}}}
0%
V prihodu
Title
  • On Stock
    On arrival
    On request
    15 days
    Mounting type