Filters
Filter type
Clear all
Expand all
Open all
Title
-
Tekst na levi
-
Tekst na levi
-
Tekst na levi
-
Tekst na levi
-
Tekst na levi
Več...
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf |
Title
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf | |
Tesfd fsf sdf sdf sdf |
PV inverters protection fuses
Items:
0
{"records":[{"ID":"49220","eti_code":"004184487","descr":"NH1 gG 80A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 80A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184487|Fuse link, NH1 gG 80A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 80A\/800V|Rated current 80A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 6,9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 77.000A2s|Prearcing joule integral 12.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 80A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"6,9","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"77.000","Prearcing_joule":"12.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184487-fuse-link-nh1-nh-nh1-80a-800v-gg"},{"ID":"49216","eti_code":"004184483","descr":"NH1 gG 35A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 35A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184483|Fuse link, NH1 gG 35A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 35A\/800V|Rated current 35A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 3,4W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 24.000A2s|Prearcing joule integral 2.200A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 35A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"35","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"3,4","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"24.000","Prearcing_joule":"2.200","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184483-fuse-link-nh1-nh-nh1-35a-800v-gg"},{"ID":"49095","eti_code":"004184482","descr":"NH1 gG 25A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 25A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184482|Fuse link, NH1 gG 25A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 25A\/800V|Rated current 25A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 3,2W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 9.000A2s|Prearcing joule integral 560A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 25A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"25","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"3,2","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"9.000","Prearcing_joule":"560","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184482-fuse-link-nh1-nh-nh1-25a-800v-gg"},{"ID":"49219","eti_code":"004184486","descr":"NH1 gG 63A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 63A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184486|Fuse link, NH1 gG 63A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 63A\/800V|Rated current 63A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 5,5W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 55.000A2s|Prearcing joule integral 6.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 63A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"5,5","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"55.000","Prearcing_joule":"6.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184486-fuse-link-nh1-nh-nh1-63a-800v-gg"},{"ID":"49222","eti_code":"004184489","descr":"NH1 gG 125A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 125A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184489|Fuse link, NH1 gG 125A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 125A\/800V|Rated current 125A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 9,7W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 145.000A2s|Prearcing joule integral 31.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 125A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"9,7","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"145.000","Prearcing_joule":"31.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"437.00","stock_status":"1","packaging_basic":"3","alias":"004184489-fuse-link-nh1-nh-nh1-125a-800v-gg"},{"ID":"49221","eti_code":"004184488","descr":"NH1 gG 100A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 100A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184488|Fuse link, NH1 gG 100A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 100A\/800V|Rated current 100A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 8,6W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 100.000A2s|Prearcing joule integral 18.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 100A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"8,6","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"100.000","Prearcing_joule":"18.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184488-fuse-link-nh1-nh-nh1-100a-800v-gg"},{"ID":"49223","eti_code":"004184490","descr":"NH1 gG 160A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 160A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184490|Fuse link, NH1 gG 160A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 160A\/800V|Rated current 160A|Type NH|Rated voltage 800V|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 12,4W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 260.000A2s|Prearcing joule integral 55.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 160A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"12,4","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"260.000","Prearcing_joule":"55.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184490-fuse-link-nh1-nh-nh1-160a-800v-gg"},{"ID":"49218","eti_code":"004184485","descr":"NH1 gG 50A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 50A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".42","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184485|Fuse link, NH1 gG 50A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 50A\/800V|Rated current 50A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 4,4W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 40.000A2s|Prearcing joule integral 3.500A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 50A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"4,4","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"40.000","Prearcing_joule":"3.500","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184485-fuse-link-nh1-nh-nh1-50a-800v-gg"},{"ID":"49217","eti_code":"004184484","descr":"NH1 gG 40A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH1 NH NH1 40A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"420","weight_em":"g","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6128_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184484|Fuse link, NH1 gG 40A\/800V|Special fuses|Fuse links gG 800V a.c.|NH1|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH1 GG 40A\/800V|Rated current 40A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 4W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 35.000A2s|Prearcing joule integral 3.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH1 NH NH1 40A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NH","size":"NH1","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"4","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"35.000","Prearcing_joule":"3.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184484-fuse-link-nh1-nh-nh1-40a-800v-gg"},{"ID":"49243","eti_code":"004184491","descr":"NH00 gG 25A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 25A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184491|Fuse link, NH00 gG 25A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 25A\/800V|Rated current 25A|Type NH|Rated voltage 800V|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 3,2W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 3.000A2s|Prearcing joule integral 1.300A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 25A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"25","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"3,2","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"3.000","Prearcing_joule":"1.300","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184491-fuse-link-nh00-nh-nh00-25a-800v-gg"},{"ID":"49244","eti_code":"004184492","descr":"NH00 gG 35A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 35A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184492|Fuse link, NH00 gG 35A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 35A\/800V|Rated current 35A|Type NH|Rated voltage 800V|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 3,8W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 6.000A2s|Prearcing joule integral 2.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 35A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"35","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"3,8","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"6.000","Prearcing_joule":"2.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184492-fuse-link-nh00-nh-nh00-35a-800v-gg"},{"ID":"49245","eti_code":"004184493","descr":"NH00 gG 40A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 40A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184493|Fuse link, NH00 gG 40A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 40A\/800V|Rated current 40A|Type NH|Rated voltage 800V|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 4W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 7.000A2s|Prearcing joule integral 2.500A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 40A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"4","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"7.000","Prearcing_joule":"2.500","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184493-fuse-link-nh00-nh-nh00-40a-800v-gg"},{"ID":"49246","eti_code":"004184494","descr":"NH00 gG 50A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 50A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184494|Fuse link, NH00 gG 50A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 50A\/800V|Rated current 50A|Type NH|Rated voltage 800V|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 5,4W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 11.000A2s|Prearcing joule integral 4.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 50A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"50","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"5,4","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"11.000","Prearcing_joule":"4.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"0.00","stock_status":"3","packaging_basic":"3","alias":"004184494-fuse-link-nh00-nh-nh00-50a-800v-gg"},{"ID":"49247","eti_code":"004184495","descr":"NH00 gG 63A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 63A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184495|Fuse link, NH00 gG 63A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 63A\/800V|Rated current 63A|Type NH|Rated voltage 800V|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 7W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 19.000A2s|Prearcing joule integral 9.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 63A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"7","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"19.000","Prearcing_joule":"9.000","Application":"For cable protection on 800V a.c. system voltage","price":"17.2933","price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":"-672.00","stock_status":"3","packaging_basic":"3","alias":"004184495-fuse-link-nh00-nh-nh00-63a-800v-gg"},{"ID":"50933","eti_code":"004184498","descr":"NH3 gG 315A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH3 NH NH3 315A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"1.05","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6430_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184498|Fuse link, NH3 gG 315A\/800V|Special fuses|Fuse links gG 800V a.c.|NH3|NH3|NH3|NH3|Special purpose fuses|PV inverters protection fuses|NH3 GG 315A\/800V|Rated current 315A|Type NH|Size NH3|Product group Fuse-link|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 29W|Catalogue Group Fuse-link|Catalogue subgroup Non standard gG Fuse|Standards IEC60269-2|Operating joule integral 1.340.000A2s|Prearcing joule integral 140.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH3 NH NH3 315A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"315","type":"NH","size":"NH3","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"29","Standards":"IEC60269-2","Power_dissip_07":"","Operating_joule":"1.340.000","Prearcing_joule":"140.000","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184498-fuse-link-nh3-nh-nh3-315a-800v-gg"},{"ID":"50932","eti_code":"004184497","descr":"NH3 gG 250A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH3 NH NH3 250A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"1.05","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6430_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184497|Fuse link, NH3 gG 250A\/800V|Special fuses|Fuse links gG 800V a.c.|NH3|NH3|NH3|NH3|Special purpose fuses|PV inverters protection fuses|NH3 GG 250A\/800V|Rated current 250A|Type NH|Size NH3|Product group Fuse-link|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 20W|Catalogue Group Fuse-link|Catalogue subgroup Non standard gG Fuse|Standards IEC60269-2|Operating joule integral 1.100.000A2s|Prearcing joule integral 85.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH3 NH NH3 250A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"250","type":"NH","size":"NH3","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"20","Standards":"IEC60269-2","Power_dissip_07":"","Operating_joule":"1.100.000","Prearcing_joule":"85.000","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184497-fuse-link-nh3-nh-nh3-250a-800v-gg"},{"ID":"50931","eti_code":"004184496","descr":"NH3 gG 200A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH3 NH NH3 200A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"1.05","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6430_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184496|Fuse link, NH3 gG 200A\/800V|Special fuses|Fuse links gG 800V a.c.|NH3|NH3|NH3|NH3|Special purpose fuses|PV inverters protection fuses|NH3 GG 200A\/800V|Rated current 200A|Type NH|Size NH3|Product group Fuse-link|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 16W|Catalogue Group Fuse-link|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 650.000A2s|Prearcing joule integral 50.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH3 NH NH3 200A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"200","type":"NH","size":"NH3","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"16","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"650.000","Prearcing_joule":"50.000","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184496-fuse-link-nh3-nh-nh3-200a-800v-gg"},{"ID":"51619","eti_code":"004184466","descr":"NH00 gG 20A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 20A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184466|Fuse link, NH00 gG 20A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 20A\/800V|Rated current 20A|Type NH|Rated voltage 800V|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 2,9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 2.000A2s|Prearcing joule integral 650A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 20A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"20","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"2,9","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"2.000","Prearcing_joule":"650","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184466-fuse-link-nh00-nh-nh00-20a-800v-gg"},{"ID":"51640","eti_code":"004725235","descr":"M3 gS 500A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M3 NH NH3 500A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".918","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004725235|Fuse link, M3 gS 500A\/800V|Special fuses|Fuse links gS 800V a.c.|NH3|NH3|NH3|NH3|Special purpose fuses|PV inverters protection fuses|M3 GS 500A\/800V|Rated current 500A|Type NH|Size NH3|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 33,5W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 2.100.000A2s|Prearcing joule integral 220.000A2s|Application Protection of inverters|Fuse link M3 NH NH3 500A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"500","type":"NH","size":"NH3","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"33,5","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"2.100.000","Prearcing_joule":"220.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004725235-fuse-link-m3-nh-nh3-500a-800v-gs"},{"ID":"51639","eti_code":"004725234","descr":"M3 gS 450A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M3 NH NH3 450A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".918","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004725234|Fuse link, M3 gS 450A\/800V|Special fuses|Fuse links gS 800V a.c.|NH3|NH3|NH3|NH3|Special purpose fuses|PV inverters protection fuses|M3 GS 450A\/800V|Rated current 450A|Type NH|Size NH3|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 31,7W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 1.750.000A2s|Prearcing joule integral 170.000A2s|Application Protection of inverters|Fuse link M3 NH NH3 450A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"450","type":"NH","size":"NH3","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"31,7","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"1.750.000","Prearcing_joule":"170.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004725234-fuse-link-m3-nh-nh3-450a-800v-gs"},{"ID":"51638","eti_code":"004725233","descr":"M3 gS 400A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M3 NH NH3 400A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".918","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004725233|Fuse link, M3 gS 400A\/800V|Special fuses|Fuse links gS 800V a.c.|NH3|NH3|NH3|NH3|Special purpose fuses|PV inverters protection fuses|M3 GS 400A\/800V|Rated current 400A|Type NH|Size NH3|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 30W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 1.200.000A2s|Prearcing joule integral 105.000A2s|Application Protection of inverters|Fuse link M3 NH NH3 400A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"400","type":"NH","size":"NH3","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"30","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"1.200.000","Prearcing_joule":"105.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004725233-fuse-link-m3-nh-nh3-400a-800v-gs"},{"ID":"51637","eti_code":"004725232","descr":"M3 gS 350A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M3 NH NH3 350A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".918","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004725232|Fuse link, M3 gS 350A\/800V|Special fuses|Fuse links gS 800V a.c.|NH3|NH3|NH3|NH3|Special purpose fuses|PV inverters protection fuses|M3 GS 350A\/800V|Rated current 350A|Type NH|Size NH3|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 25W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 980.00A2s|Prearcing joule integral 85.000A2s|Application Protection of inverters|Fuse link M3 NH NH3 350A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"350","type":"NH","size":"NH3","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"25","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"980.00","Prearcing_joule":"85.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004725232-fuse-link-m3-nh-nh3-350a-800v-gs"},{"ID":"51636","eti_code":"004724235","descr":"M2 gS 400A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M2 NH NH2 400A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".708","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6542_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004724235|Fuse link, M2 gS 400A\/800V|Special fuses|Fuse links gS 800V a.c.|NH2|NH2|NH2|NH2|Special purpose fuses|PV inverters protection fuses|M2 GS 400A\/800V|Rated current 400A|Type NH|Size NH2|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 30W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 1.020.000A2s|Prearcing joule integral 95.000A2s|Application Protection of inverters|Fuse link M2 NH NH2 400A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"400","type":"NH","size":"NH2","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"30","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"1.020.000","Prearcing_joule":"95.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004724235-fuse-link-m2-nh-nh2-400a-800v-gs"},{"ID":"51635","eti_code":"004724234","descr":"M2 gS 350A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M2 NH NH2 350A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".708","weight_em":"kg","basic_packaging":"3","shipping_packaging":"15","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6542_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004724234|Fuse link, M2 gS 350A\/800V|Special fuses|Fuse links gS 800V a.c.|NH2|NH2|NH2|NH2|Special purpose fuses|PV inverters protection fuses|M2 GS 350A\/800V|Rated current 350A|Type NH|Size NH2|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 25W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 825.000A2s|Prearcing joule integral 70.000A2s|Application Protection of inverters|Fuse link M2 NH NH2 350A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"350","type":"NH","size":"NH2","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"25","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"825.000","Prearcing_joule":"70.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004724234-fuse-link-m2-nh-nh2-350a-800v-gs"},{"ID":"51634","eti_code":"004723237","descr":"M1 gS 315A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M1 NH NH1 315A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".64","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6541_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004723237|Fuse link, M1 gS 315A\/800V|Special fuses|Fuse links gS 800V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|PV inverters protection fuses|M1 GS 315A\/800V|Rated current 315A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 28W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 490.000A2s|Prearcing joule integral 35.000A2s|Application Protection of inverters|Fuse link M1 NH NH1 315A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"315","type":"NH","size":"NH1","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"28","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"490.000","Prearcing_joule":"35.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723237-fuse-link-m1-nh-nh1-315a-800v-gs"},{"ID":"51633","eti_code":"004723236","descr":"M1 gS 250A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M1 NH NH1 250A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".64","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6541_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004723236|Fuse link, M1 gS 250A\/800V|Special fuses|Fuse links gS 800V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|PV inverters protection fuses|M1 GS 250A\/800V|Rated current 250A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 22W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 275.000A2s|Prearcing joule integral 18.000A2s|Application Protection of inverters|Fuse link M1 NH NH1 250A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"250","type":"NH","size":"NH1","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"22","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"275.000","Prearcing_joule":"18.000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723236-fuse-link-m1-nh-nh1-250a-800v-gs"},{"ID":"51632","eti_code":"004723235","descr":"M1 gS 200A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M1 NH NH1 200A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".64","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6541_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004723235|Fuse link, M1 gS 200A\/800V|Special fuses|Fuse links gS 800V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|PV inverters protection fuses|M1 GS 200A\/800V|Rated current 200A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 19W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 145.000A2s|Prearcing joule integral 9000A2s|Application Protection of inverters|Fuse link M1 NH NH1 200A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"200","type":"NH","size":"NH1","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"19","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"145.000","Prearcing_joule":"9000","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723235-fuse-link-m1-nh-nh1-200a-800v-gs"},{"ID":"51631","eti_code":"004723234","descr":"M1 gS 160A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link M1 NH NH1 160A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":".64","weight_em":"kg","basic_packaging":"3","shipping_packaging":"24","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6541_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004723234|Fuse link, M1 gS 160A\/800V|Special fuses|Fuse links gS 800V a.c.|NH1|NH1|NH1|NH1|Special purpose fuses|PV inverters protection fuses|M1 GS 160A\/800V|Rated current 160A|Type NH|Size NH1|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 120kA|Power dissipation 17W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 110.000A2s|Prearcing joule integral 3500A2s|Application Protection of inverters|Fuse link M1 NH NH1 160A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"160","type":"NH","size":"NH1","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"120","breaking_capacity_dc":"","pd_w":"17","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"110.000","Prearcing_joule":"3500","Application":"Protection of inverters","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004723234-fuse-link-m1-nh-nh1-160a-800v-gs"},{"ID":"51624","eti_code":"004184503","descr":"NH00 gS 125A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 125A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184503|Fuse link, NH00 gS 125A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 125A\/800|Rated current 125A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 12,9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 72.000A2s|Prearcing joule integral 4.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 125A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"125","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"12,9","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"72.000","Prearcing_joule":"4.000","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184503-fuse-link-nh00-nh-nh00-125a-800v-gs"},{"ID":"51621","eti_code":"004184500","descr":"NH00 gS 100A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 100A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184500|Fuse link, NH00 gS 100A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 100A\/800|Rated current 100A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 9W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 60.000A2s|Prearcing joule integral 60.000A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 100A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"100","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"9","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"60.000","Prearcing_joule":"60.000","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184500-fuse-link-nh00-nh-nh00-100a-800v-gs"},{"ID":"51622","eti_code":"004184501","descr":"NH00 gS 80A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 80A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184501|Fuse link, NH00 gS 80A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 80A\/800V|Rated current 80A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 6,7W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 32.000A2s|Prearcing joule integral 1.360A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 80A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"80","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"6,7","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"32.000","Prearcing_joule":"1.360","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184501-fuse-link-nh00-nh-nh00-80a-800v-gs"},{"ID":"51623","eti_code":"004184502","descr":"NH00 gS 63A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 63A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184502|Fuse link, NH00 gS 63A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 63A\/800V|Rated current 63A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 6,2W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 18.400A2s|Prearcing joule integral 510A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 63A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"63","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"6,2","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"18.400","Prearcing_joule":"510","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184502-fuse-link-nh00-nh-nh00-63a-800v-gs"},{"ID":"51618","eti_code":"004184465","descr":"NH00 gG 16A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 16A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184465|Fuse link, NH00 gG 16A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 16A\/800V|Rated current 16A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 2,5W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 960A2s|Prearcing joule integral 340A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 16A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"16","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"2,5","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"960","Prearcing_joule":"340","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184465-fuse-link-nh00-nh-nh00-16a-800v-gg"},{"ID":"51620","eti_code":"004184499","descr":"NH00 gG 10A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 10A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184499|Fuse link, NH00 gG 10A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 10A\/800V|Rated current 10A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 1,3W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 600A2s|Prearcing joule integral 180A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 10A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"10","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"1,3","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"600","Prearcing_joule":"180","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184499-fuse-link-nh00-nh-nh00-10a-800v-gg"},{"ID":"51617","eti_code":"004184464","descr":"NH00 gG 6A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 6A 800V gG","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6138_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184464|Fuse link, NH00 gG 6A\/800V|Special fuses|Fuse links gG 800V a.c.|NH00|KOMBI|KOMBI|KOMBI|Special purpose fuses|PV inverters protection fuses|NH00 GG 6A\/800V|Rated current 6A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gG|Characteristics gG|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 1,5W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gG Fuse|Standards IEC 60269-2|Operating joule integral 240A2s|Prearcing joule integral 120A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 6A 800V gG|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"6","type":"NH","size":"NH00","charact":"gG","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"1,5","Standards":"IEC 60269-2","Power_dissip_07":"","Operating_joule":"240","Prearcing_joule":"120","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184464-fuse-link-nh00-nh-nh00-6a-800v-gg"},{"ID":"51625","eti_code":"004184504","descr":"NH00 gS 16A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 16A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184504|Fuse link, NH00 gS 16A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 16A\/800V|Rated current 16A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 3,1W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 1.000A2s|Prearcing joule integral 15A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 16A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"16","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"3,1","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"1.000","Prearcing_joule":"15","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184504-fuse-link-nh00-nh-nh00-16a-800v-gs"},{"ID":"51626","eti_code":"004184505","descr":"NH00 gS 20A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 20A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184505|Fuse link, NH00 gS 20A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 20A\/800V|Rated current 20A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 3,2W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 1.200A2s|Prearcing joule integral 32A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 20A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"20","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"3,2","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"1.200","Prearcing_joule":"32","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184505-fuse-link-nh00-nh-nh00-20a-800v-gs"},{"ID":"51627","eti_code":"004184506","descr":"NH00 gS 25A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 25A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184506|Fuse link, NH00 gS 25A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 25A\/800V|Rated current 25A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 4,3W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 1.600A2s|Prearcing joule integral 54A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 25A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"25","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"4,3","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"1.600","Prearcing_joule":"54","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184506-fuse-link-nh00-nh-nh00-25a-800v-gs"},{"ID":"51628","eti_code":"004184507","descr":"NH00 gS 35A\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 35A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184507|Fuse link, NH00 gS 35A\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 35A\/800V|Rated current 35A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 4,3W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 5.500A2s|Prearcing joule integral 250A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 35A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"35","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"4,3","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"5.500","Prearcing_joule":"250","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184507-fuse-link-nh00-nh-nh00-35a-800v-gs"},{"ID":"51629","eti_code":"004184508","descr":"NH00 gS 40\/800V","descr_uk_UA":"\u0417\u0430\u043f\u043e\u0431\u0456\u0436\u043d\u0438\u043a","descr_uk_RU":"\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c","seo_name":"Fuse link NH00 NH NH00 40A 800V gS","seo_alias":null,"class_name":"Fuse link","id_level":"457","weight":"190","weight_em":"g","basic_packaging":"3","shipping_packaging":"90","stock_type":"pcs","file_link":"\/images\/product_db\/levels\/en-GB\/6539_photo.jpg","tree_depth":"2","tree_title":"PV inverters protection fuses","program_type":"1","searchstring":"|004184508|Fuse link, NH00 gS 40\/800V|Special fuses|Fuse links gS 800V a.c.|NH00|NH00|NH00|NH00|Special purpose fuses|PV inverters protection fuses|NH00 GS 40\/800V|Rated current 40A|Type NH|Size NH00|Product group Special purpose fuses|Product subgroup Non standard gS|Characteristics gS|Rated AC voltage 800V|Indicator Top fuse status indicator|Breaking capacity AC 30kA|Power dissipation 4,5W|Catalogue Group Special purpose fuses|Catalogue subgroup Non standard gS Fuse|Standards IEC 60269-4|Operating joule integral 6.300A2s|Prearcing joule integral 390A2s|Application For cable protection on 800V a.c. system voltage|Fuse link NH00 NH NH00 40A 800V gS|","stockammount":"0","stockstatus":"0","preview_mode":"0","rated_current":"40","type":"NH","size":"NH00","charact":"gS","rated_ac_voltage":"800","rated_dc_voltage":"","dimensions":"","indicator":"Top fuse status indicator","breaking_capacity_ac":"30","breaking_capacity_dc":"","pd_w":"4,5","Standards":"IEC 60269-4","Power_dissip_07":"","Operating_joule":"6.300","Prearcing_joule":"390","Application":"For cable protection on 800V a.c. system voltage","price":null,"price_web":null,"price_action":null,"price_discount_web":null,"price_discount_action":null,"vat":null,"stock":null,"stock_status":null,"packaging_basic":null,"alias":"004184508-fuse-link-nh00-nh-nh00-40a-800v-gs"}],"columns":[{"name":"eti_code","title":"ETI Code","primary":true},{"name":"descr","title":"Description","primary":false},{"name":"class_name","title":"Class name","primary":false},{"name":"type","title":"Type","primary":false},{"name":"Price","title":"COM_ETIB2B_ORDERS_TABLE_COLUMN_PRICE","cssClass":"price align-right","primary":false},{"name":"StockStatus","title":"COM_ETIB2B_ORDERS_TABLE_COLUMN_AVAILABILITY","primary":false},{"name":"Commands","title":"","primary":false}],"recordsCount":40,"recordsTotalCount":41,"params":{"filters":{"lang":"en-GB","levelId":457,"status":null,"search":null,"programType":"actual"},"pageNumber":1,"pageSize":40,"pageMax":2,"dataEx":{"filterItems":{"type":{"field":"type","values":[{"count":"41","value":"NH"}],"trans":"Type"},"size":{"field":"size","values":[{"count":"19","value":"NH00"},{"count":"13","value":"NH1"},{"count":"2","value":"NH2"},{"count":"7","value":"NH3"}],"trans":"Size"},"rated_current":{"field":"rated_current","values":[{"count":"1","value":"6"},{"count":"1","value":"10"},{"count":"2","value":"16"},{"count":"2","value":"20"},{"count":"3","value":"25"},{"count":"3","value":"35"},{"count":"3","value":"40"},{"count":"3","value":"50"},{"count":"3","value":"63"},{"count":"2","value":"80"},{"count":"2","value":"100"},{"count":"2","value":"125"},{"count":"2","value":"160"},{"count":"2","value":"200"},{"count":"2","value":"250"},{"count":"2","value":"315"},{"count":"2","value":"350"},{"count":"2","value":"400"},{"count":"1","value":"450"},{"count":"1","value":"500"}],"trans":"Rated current (A)"},"rated_ac_voltage":{"field":"rated_ac_voltage","values":[{"count":"41","value":"800"}],"trans":"Rated AC voltage (V)"},"rated_dc_voltage":{"field":"rated_dc_voltage","values":[],"trans":"Rated DC voltage (V)"},"charact":{"field":"charact","values":[{"count":"21","value":"gG"},{"count":"20","value":"gS"}],"trans":"Characteristics"}},"columnsThumbs":[{"column":"class_name","title":"Class name"},{"column":"type","title":"Type"},{"column":"size","title":"Size"},{"column":"rated_current","title":"Rated current (A)"},{"column":"rated_ac_voltage","title":"Rated AC voltage (V)"}],"columnsThumbsAll":[{"column":"class_name","title":"Class name"},{"column":"type","title":"Type"},{"column":"size","title":"Size"},{"column":"rated_current","title":"Rated current (A)"},{"column":"rated_ac_voltage","title":"Rated AC voltage (V)"},{"column":"rated_dc_voltage","title":"Rated DC voltage (V)"},{"column":"charact","title":"Characteristics"},{"column":"breaking_capacity_ac","title":"Breaking capacity AC (kA)"},{"column":"breaking_capacity_dc","title":"Breaking capacity DC (kA)"},{"column":"Application","title":"Application"}],"programTypes":{"1":{"program_type":"1","Count":"41"}}}}}